Import CertsGet a quote

What is 16 CFR 1201, and what does Category II mean?

16 CFR part 1201 is CPSC's safety standard for glazing in storm doors, doors, shower and bathtub enclosures and sliding patio doors. Category II covers shower and tub enclosures, patio doors and doors with any glazing over 9 square feet. Importers of these products need a General Certificate of Conformity, eFiling citation code 1201.

Reviewed November 2026. Checked against 7 sources, listed at the end of the page.

Architectural glazing materialsRule record
Rule
16 CFR part 1201Safety Standard for Architectural Glazing Materials
Covers
Safety glazing for doors and shower enclosures
Standard
ANSI Z97.1-2015
Certificate
General Certificate of Conformity (GCC)
Third-party testing
Not required to be third party: a test of each product or a reasonable testing program, by any qualified lab or the firm itself
eFiling citation code
1201
Registration card
Not required by part 1130
Current text since
April 22, 201681 FR 15427
Checked against the eCFR and CPSC's code list on November 23, 2026

What the rule covers

Glazing used in storm doors, doors, bathtub doors and enclosures, shower doors and enclosures, and sliding patio doors, and those products when they contain glazing (16 CFR 1201.1(a)).

(a) Scope. This part 1201, a consumer product safety standard, prescribes the safety requirements for glazing materials used or intended for use in any of the following architectural products: (1) Storm doors or combination doors. (2) Doors. (3) Bathtub doors and enclosures. (4) Shower doors and enclosures. (5) [Reserved] (6) Sliding glass doors (patio-type).ยง 1201.1 Scope, application and findings, eCFR

The rule that adopted the current edition, 81 FR 15427, took effect on April 22, 2016. Federal Register.

Category I and Category II

CategoryProductsSource
Category I (Class B)Storm doors, combination doors and doors with no single piece of glazing over 9 square feet16 CFR 1201.2(a)(3)
Category II (Class A)Shower doors and enclosures, bathtub doors and enclosures, sliding patio doors, and storm doors, combination doors or doors with any piece of glazing over 9 square feet16 CFR 1201.2(a)(4)

A mark such as "16 CFR 1201 II" on shower or patio door glass refers to this part and to Category II as defined in 16 CFR 1201.2(a)(4). Glazing is tested under the applicable provisions of ANSI Z97.1-2015 (16 CFR 1201.4).

What is exempt

Wired glass required by a fire ordinance, louvers of jalousie doors, door openings a 3 inch sphere cannot pass through, and some carved, dalle or leaded decorative glass are exempt (16 CFR 1201.1(c)). Glazing in mobile homes is not covered (16 CFR 1201.1(b)).

Which certificate, and who tests

This is a general-use rule, so a General Certificate of Conformity is based on a test of each product or a reasonable testing program. CPSC says first-party testing, or testing by any qualified lab, can support a GCC; a CPSC-accepted lab is not required.

If the GCC relies on a third-party lab's results, that lab is still listed on the certificate. See General Certificate of Conformity.

What goes on the certificate and what is filed

For each product under this rule, the certificate data goes to CBP in ACE with every entry. Your broker sends either all of the data elements in a Full PGA Message Set, or the Certifier ID, Product ID and Version ID of a certified record in the CPSC Product Registry in a Reference PGA Message Set. The certificate lists this rule as citation code 1201, plus a code for every other rule the product is certified to.

If a testing exclusion applies to a cited rule, the certificate lists the exclusion code in place of the test date and lab for that rule (16 CFR 1110.11(c)). See citation codes and the seven data elements.

Certificate record: Architectural glazing materialsSample
General Certificate of ConformityExampleCo / EX-1001 / V1
Product ID
EX-1001SKU, primary ID
Citations
  • 1201Safety Standard for Architectural Glazing Materials
Manufactured
09/2026, Example Manufacturing Co. Ltd.Street address, city, country, email and phone
Last tested
08/2026, Example Test Lab, or the importer's own testing programAddress, email and phone
Test records
Compliance Manager, Example Co.
Certifier
Example Co., importer of record
Sample for a fictional importer. Cite every rule that applies to your product.

Common questions

What does 16 CFR 1201 II mean on shower glass?

It refers to 16 CFR part 1201 and Category II, the category that includes shower doors and enclosures (16 CFR 1201.2(a)(4)).

Which test standard applies?

The applicable test provisions of ANSI Z97.1-2015 (16 CFR 1201.4).

Want the certificate records built for you?

We set up your CPSC Product Registry account, build a certificate record for each product from your test reports, and give your broker the identifiers. Setup is $1,500 for up to 25 products.